What is Class B fire extinguisher name?

What do the A B C ratings mean on Fire Extinguishers?

What is Class B fire extinguisher name?
“A” TRASH–WOOD–PAPER

Fire extinguishers with a Class A rating are effective against fires involving paper, wood, textiles, and plastics. The primary chemical used to fight these fires is monoammonium phosphate, because of its ability to smother fires in these types of materials.

What is Class B fire extinguisher name?
“B” LIQUIDS

Fire extinguishers with a Class B rating are effective against flammable liquid fires. These can be fires where cooking liquids, oil, gasoline, kerosene, or paint have become ignited. Two commonly used chemicals are effective in fighting these types of fires. Monoammonium phosphate effectively smothers the fire, while sodium bicarbonate induces a chemical reaction which extinguishes the fire.

What is Class B fire extinguisher name?
“C” ELECTRICAL EQUIPMENT

Fire extinguishers with a Class C rating are suitable for fires in “live” electrical equipment. Both monoammonium phosphate and sodium bicarbonate are commonly used to fight this type of fire because of their nonconductive properties.

Fire Extinguisher Ratings 

Fire extinguishers are classified by fire type. The A, B, C rating system defines the kinds of burning materials each fire extinguisher is designed to fight. The number in front of the A, B, or C indicates the rating size of fire the unit can extinguish.

To achieve a Class “A” rating, the extinguisher must be capable of putting out the wood crib, wood panel and excelsior (shredded paper) tests. Ratings are based on the size of the material that can be repeatedly extinguished.


RatingWood Crib
(inches)
Wood Panel
(Feet)
Excelsior
(lbs)
1-A20 x 20 x 208 x 86
2-A25 x 26 x 2610 x 1012
3-A30 x 30 x 3012 x 1218
4-A33 x 30 x 3014 x 1424
6-A38x 38 x 3817 x 1736
10-A48 x 48 x 4817 x 1736

To achieve a class “B” rating, the extinguisher must repeatedly put out a flaming liquid fire. Ratings are based on the size of the fire.

RatingPan Size
(sq ft)
Gallons of
Heptane
1-B2.53.25
2-B5.06.25
5-B12.515.5
10-B25.031.0
20-B50.065.0
30-B75.095.0
40-B100.0125.0

To achieve the Class “C” rating the extinguisher and contents must pass certain electrical conductivity measurements in accordance with UL711 and UL299.


Page 2

The 10-Year product lineup provides hands off, maintenance free devices that are a small investment in the future. Choose from a variety of alarm styles and options to best fit your job - we offer:

Hardwired with 10-Year sealed battery backup or Battery powered with a 10-Year sealed lithium power cell battery

What is Class B fire extinguisher name?

In the unfortunate event of a fire, having a fire extinguisher on hand is vital. It could help you save your property… or even your life.

Every fire is different. Depending on the flammable materials involved, you may need to use a specific type of fire extinguisher. If you choose the wrong type, it could be ineffective or dangerous.

Understanding the different classes of fire can help you to identify which types of fire extinguishers you need for adequate fire protection for your commercial site.

What is Class B fire extinguisher name?

Different classes of fire

There are six classes of fire:

  • Class A – Normal combustibles such as wood or plastic
  • Class B – Flammable liquids such as petrol or paint
  • Class C – Combustible gases such as LPG gas or natural gas
  • Class D – Flammable metals such as magnesium
  • Class E – Electrically energised equipment such as short-circuited machinery or overloaded electrical cables
  • Class F – Cooking oils such as vegetable oil, fats and lard.

Types of fire extinguishers

Each type of fire involves different flammable materials and requires a specific approach. Because of this there are five main types of fire extinguishers. And the simplest way to identify the contents of the fire extinguisher is by its coloured band.

Water fire extinguishers (No band – all red)

Suitable to extinguish Class A fires involving wood, paper, cloth, rubber, plastics, grass or coal. But it is important to be aware that you should not use this type of extinguisher for Class E – electrical fires – as it has the potential to conduct electricity and electrocute someone.

Foam fire extinguishers (Blue)

Suitable to extinguish Class A and B fires involving flammable and combustible liquids such as petrol, kerosene, oil, paint and wax.

What is Class B fire extinguisher name?

This is the most popular type of fire extinguisher, due to its extremely wide variety of uses. There are two commonly used dry chemical powder extinguisher types – ABE and BE.

As its name suggests, the ABE is suitable to extinguish various classes of fire involving wood, paper, petrol or electrical cables (up to 1000 volts), whereas the BE is suitable for petrol, electrical cables (up to 1000 volts) and Class F cooking oils. Both are also suitable for Class C fire types.

Suitable for Class E fires. Generally not suitable for outdoor use.

Wet Chemical fire extinguisher (Oatmeal)

Suitable for Class F fire involving cooking oils and fats, as well as Class A fires – wood, paper, cloth, rubber, plastics, grass and coal. You should install this type of extinguishers in commercial cooking settings.

What is Class B fire extinguisher name?

How to use a fire extinguisher

All fire extinguishers in Australia are designed to be operated using the PASS technique:

  • Pull the pin.
  • Aim it at the fire.
  • Squeeze the handle.
  • Sweep from side to side.

What is Class B fire extinguisher name?

Complying with fire protection regulations

Fire extinguishers in a commercial premise should be stored so they are easy to access but are away from areas likely to catch fire.

Business owners need to comply with their relevant government fire protection regulations. This includes the types and number of fire extinguishers on-site, correct installation and ongoing maintenance.

Experts in fire extinguishers

DEM Fire looks after every aspect of your fire protection design, installation and maintenance – and that includes all certification and reporting. Our on-staff accredited fire protection experts complete all client reports. We never outsource because we have the best people right here. Our staff members are industry leaders – with decades of experience and industry knowledge.

Please get in touch for help on choosing the right fire extinguisher for your business. Read more Fire Protection articles.

No single extinguisher can be used to tackle every fire, and because each type of fire extinguisher has different categories of fire on which it is effective, selection can be a minefield. The good news is that portable fire extinguishers are effective and are saving lives. According to a survey from companies in the four main trade associations in the UK fire sector, the number of fires being successfully extinguished by portable devices has increased from 80% in 2003 to 93% in 2021.

The first step is to look at what materials are present in the area to be protected from fire. These can be divided into six fire classes involving different substances:

  • Class A fire caused by combustible carbon-based solids such as paper, wood or textiles
  • Class B fire caused by flammable liquids eg paraffin, petrol, diesel or oil (but not cooking oil)
  • Class C fire caused by flammable gases, eg butane, propane or methane
  • Class D fire caused by burning metals, eg aluminium, lithium or magnesium
  • Fires caused by electrical equipment (indicated by an electric spark symbol and not the letter E)
  • Class F fire caused by fats and cooking oils.

In the UK, portable fire extinguishers must conform to BS EN3 Standard, which specifies that their body is coloured red. A small coloured band indicates the type of fire extinguisher – red for water, white and red for water mist, cream colour for foam, blue for dry powder, yellow coded extinguishers are used for wet chemical, green for clean agent and black for CO2 extinguishers.

Want to find out more about the latest legislation and news in the fire safety sector?

Download our free Fire Safety in 2021 Annual Report, here >> 

The prices of all extinguishers vary widely according to supplier, so purchasers are advised to shop around. The future cost of servicing will also need to be taken into consideration. Some firms charge for installation and commissioning, but they should be supplied with a 5-year warranty and mounting brackets included. Approximate prices given below include VAT.

Five main types of fire extinguishers

There are five different fire extinguishers, which are:

  • Water, water mist or water spray fire extinguishers
  • Foam fire extinguishers
  • Dry Powder – standard or specialist fire extinguishers
  • Carbon Dioxide (‘CO2’) fire extinguishers
  • Wet Chemical fire extinguishers

Fire extinguisher types chart

This chart visualises the fire extinguisher types used in the UK and the types of fire for which they are suitable, as well as their colour codes.

What is Class B fire extinguisher name?

Fire extinguisher types and colours in the UK. Credit to Margarita Emmanuelli on Pinterest for this chart.

As you can see from the following chart, there are 5 fire extinguisher colours in the UK: Red, Cream, Blue, Black and Yellow

Fire extinguisher types and uses

Water fire extinguishers (red label)

Water extinguishers are only used for Class A fires. Therefore, red coded extinguishers can be used to tackle fires caused by ignited paper, wood, straw, coal, rubber, solid plastics and soft furnishings. Water fire extinguishers work by spraying water from the spray nozzle, which helps to cover larger surface area. They are the simplest, most common, and least expensive type of extinguisher, costing from around £25 for 3- or 6-litre, to £35 for 9-litre ordinary models, and £50 for freeze-protected extinguishers. Some have an additive to make the water more effective and reduce the required size and weight of the extinguisher – these are a little more expensive.

Water extinguishers are the easiest to maintain variety and the least hazardous, since they only contain water. They cool the fire by soaking it and the materials with water. This extinguishes the flames, absorbing heat from burning objects.

They are often found in shops, offices, retail premises, schools, hotels, warehouses and domestic premises. They may have spray or jet nozzles and are usually able to put out a fire completely. A drawback is that they cannot be used on burning fat or oil (Class F), burning metals (Class D), burning liquids (Class B) or electrical appliance fires.

Water mist extinguishers

The newest type of extinguisher. These very powerful, but smaller, devices exude an ultra-fine mist of microscopic ‘dry’ demineralised water particles. They are safe and effective to use on Class A, B, C and F fires, making it unnecessary to supply more than one type of extinguisher in most premises. Some water mist extinguishers are also suitable for use on electrical fires on equipment up to 1,000 Volts, such as computers and printers.

They work by cooling the fire and reducing the oxygen supply. These devices are likely to replace wet chemical extinguishers for the extinction of deep fat fryer fires, and leave no residue or collateral damage. Like water extinguishers, they are recyclable and do not contain any chemicals. However, they cannot be used on Class D fires (metals).

Water mist extinguishers are more expensive than water extinguishers, costing from around £50 for 1 litre to £100 for 6 litres.

Water spray fire extinguishers

Available in three and six litres, water spray fire extinguishers are suitable to fires involving organic solid materials such as wood, cloth, paper, plastics or coal. Use on burning fat or oil or on electrical appliances is a big no-no.

Use involves pointing the jet at the base of the flames and moving it constantly and steadily across the fire until extinguished.

What is Class B fire extinguisher name?

Example of a CO2 fire extinguisher and water-based fire extinguisher in an office

A jet nozzle is eschewed in favour of a spray nozzle, which creates a fine spray courtesy of the higher pressure. Hitting a broader surface area this extracts heat more rapidly. Surfactants can be added to help the water penetrate further into burning material.

Foam extinguishers (cream label)

The foam smothers the fire in solids and liquids (Class A and B), but not in burning fats or cooking oils (Class F), so foam fire extinguishers are used on burning liquids such as petrol, paint or turpentine.  A foam extinguisher can also be used on some electrical fires if they have been tested and if fired from 1 metre away. However, they leave a residue that has to be cleaned up, and they are more expensive than water extinguishers, at around £25 for 1 litre and £55 for 9 litres.

Dry powder extinguishers (blue label)

Powder fire extinguishers are used for fighting burning solids, liquids and gases (Class A, B and C fires). Specialist powder extinguishers are designed to tackle type D fires involving combustible metals such as lithium, magnesium, or aluminium.

They work by the powder forming a crust which smothers the fire and stops it from spreading.

Disadvantages are that the powder does not soak into materials and does not have an effective cooling effect on the fire, which can result in the fire reigniting. The powder is hazardous if inhaled, so they should be used in well-ventilated areas and are not suitable for offices and domestic premises. The powder damages soft furnishings, machinery, etc, and needs a lot of cleaning up after use. They cannot be used on chip pan fires (Class F).

They are generally inexpensive and powerful and come in 1, 2, 4, 6 and 9-kg sizes. A 1kg model can cost as little as £15, while 9kg will cost around £35.

CO2 extinguishers (black label)

These contain only pressurised carbon dioxide gas and therefore leave no residue. Carbon Dioxide (CO2) extinguishers are used on fires involving burning liquids (Class B), and electrical fires, such as of large computer equipment, so are practical in offices. CO2 works by suffocating the fire and does not cause damage to the electrical items or cause the system to short circuit.

However, CO2 extinguishers get very cold during discharge, and those that are not fitted with double-lined, frost-free swivel horns may cause fingers to freeze to the horn during deployment. They can asphyxiate in confined spaces, and they are not suitable for deep fat fryers, as the strong jet from the extinguisher can carry the burning fat out of the fryer. Fires can quickly re-ignite once the CO2 has dissipated into the atmosphere, so they do not offer post-fire security.

CO2 extinguishers are quite expensive. A 2kg model costs around £33, while a 5kg model, suitable for server rooms and factories, costs from £65.

Wet chemical extinguishers (yellow label)

These are the only extinguishers apart from water mist suitable for Class F oil fires (fats and cooking oils) and are mainly used in kitchens with deep fat fryers. They can also be used on Class A and some can be used on Class B fires. They consist of a pressurised solution of alkali salts in water, which, when operated, creates a fine mist, cooling the flames and preventing splashing. More expensive than some others, they cost around £35 for 2-litre, £70 for 3-litre and £110 for 6-litre sizes.

What is Class B fire extinguisher name?

A dry powder fire extinguisher

Which fire extinguisher types to use

  • Class A fire extinguisher – water, water mist, foam, dry powder, wet chemical
  • Class B fire extinguisher – water mist, foam, dry powder, CO2, some wet chemical
  • Class C fire extinguisher – water mist, dry powder
  • Class D fire extinguisher – specialist dry powder
  • Electrical fire extinguisher – CO2
  • Class F fire extinguisher – water mist, wet chemical.

Fire extinguishers for electrical fires

In 2017, it was reported that nearly four in 10 construction workers were using the wrong type of fire extinguisher to deal with electrical fires – a survey revealed. In addition, electrical fires have become more common causes of fire due to a greater reliance on electrical products and batteries. In 2021, electricity was the top reported cause of fire (19%) according to a fire industry survey, so it’s important to know which extinguishant should be used.

For electrical fires, CO2 fire extinguishers should be used. By displacing the oxygen in the air, they help to suffocate the fire and prevent it from spreading, while leaving no residue, making them harmless to electrical equipment. They are often found in data/computer server rooms, offices, kitchens and construction sites for this very reason.

Dry powder extinguishers, which have a blue label, are said to be OK to use on electrical fires involving equipment under 1000v, though CO2 extinguishers are still advised.

When an electrical fire is taking place, respondents should not use water-based, foam, or wet chemical extinguishers.

How to use a fire extinguisher

Fire extinguishers should ideally only be used by someone who has been trained to do so – and the following text does not count as training. Moreover, a fire extinguisher should only be activated once the fire alarm has been triggered and you have identified a safe evacuation route. Evacuate the building immediately if you still feel unsure about using a fire extinguisher or if doing so is clearly the safest option.

Nevertheless, the following technique can serve as a refresher for those who have undertaken training or if someone without training ever needs to use one in order to improve the chances that everyone escapes unharmed.

The following four-step technique can be memorised more easily with the acronym PASS, to help you use a fire extinguisher:

  1. Pull: Pull the pin to break the tamper seal.
  2. Aim: Aim low, pointing the nozzle or hose at the base of the fire. (Do not touch the horn on a CO2 extinguisher since it becomes very cold and can damage skin.
  3. Squeeze: Squeeze the handle to release the extinguishing agent.
  4. Sweep: Sweep from side to side at the base of the fire – the fuel source – until the fire is extinguished.

Read more on how to use a fire extinguisher safely and effectively.

Key tips from the Fire Protection Association on using a fire extinguisher include:

  • Never use a fire extinguisher on flames from a fire involving escaping gas
  • Only tackle a fire in its earliest stages
  • Do not move forward unless it is safe, and you should always remain at least one metre from the fire
  • Do not use more than one fire extinguisher to tackle a fire

Fire blankets, hoses and buckets

These methods of fire extinction are useful additions to extinguishers.

Fire buckets can be used filled with water on Class A fires, or with sand to use as an absorbing agent for Class B fires, which are spilled flammable liquids. They must not be used with water on burning fat or oil or on electrical appliances. However, they’re sometimes left empty or misused and have a limited effect as they can’t used on large fires. Plastic fire buckets with lids cost around £15, while metal ones can be bought for around £23.

Fire hoses let out water at high pressure. They can be effective on Class A fires, but are very heavy. Prices of hose reels start at around £100 and vary widely depending on size and mounting.

Fire blankets are effective in smothering small fires in kitchens or boats, if a good seal is made, and for wrapping round people whose clothing is on fire. Made of fibreglass, they can withstand temperatures of up to 500° C and are compact and portable. They don’t need any maintenance but can only be used once. They are cheap, and can be purchased for as little as £7 for a one-metre square blanket. Larger sizes cost around £15.

Automatic fire extinguishers

Automatic fire extinguishers are designed to combat fires in transport, such as in the engine compartments of boats or large vehicles, or in industrial use, such as in generator or computer rooms. Advantages include easy recharging and lack of constant monitoring, and removal of the need for manual operation in unmanned areas.

These extinguishers are designed to spring into action when they detect heat. On the downside, their placing is crucial, since they could be set off erroneously when the ambient temperature reaches the trigger level.

Available as dry powder (blue) or clean, inert extinguishing gas, which replaces the now illegal halon, banned in the UK because of its effect on the ozone layer (green), they protect against Class A, B, C and electrical fires.

They cost from £30 to £85 for smaller models; complete systems can cost from £500 to £1,750.

Vehicle fire extinguishers

Generally containing dry powder for tackling Class A, B and C fires, their size should be selected according to the size and type of vehicle. They can be bought for around £11 for a 600g model to £70 for 12kg for larger vehicles. Their use is advisable, but is not a legal requirement in ordinary cars.

Fire extinguisher covers

Cost between £8-£25 depending on size and are used to protect extinguishers in harsh environments. Hose reel covers are also available.

Further reading

Want to know more about fire extinguishers? Why not check out some of our related articles below…

Read more fire safety news, features and guides.